Home > File Status > Vsam File Status 90 In Cobol

Vsam File Status 90 In Cobol

Contents

You can check them in the same way that you check VSAM files. For the COBOL environment if the FILE STATUS clause is specified in the FILE-CONTROL entry, a value is placed in the specified status key (the 2-character data item named in the Btw verify Operand is explained in detail in IDCAMS manual along with examples here http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/dgt1v403/3.27?DT=19990113080956 Kolusu_________________Kolusu - DFSORT Development Team (IBM) DFSORT is on the Web at: www.ibm.com/storage/dfsort Back to top The combinations of possible values and their meanings are shown below. http://digitalfishbowl.net/file-status/vsam-file-status-92-in-cobol.html

However there are many other ways when you would get a filestatus of 90. Registration on or use of this site constitutes acceptance of our Privacy Policy. It is about combining the latest technologies and existing technologies with practical business experience. My problem is that COBOL thinks that there are still records to read based on the information in this binary file (copied from another).

Vsam File Status 90 In Cobol

For files with variable-length records the minimum and maximum record lengths for the actual file may not match the minimum and maximum record lengths used by the program 41 An OPEN STL filesystem generates some header bytes in the seq files. The following tables contain file-status-key content that may be set by Micro Focus COBOL (Mainframe Express or Net Express) or an IBM Mainframe System (MVS, OS/390 or ZOS). And verify wouldn't solve it. 1.

Trying to open a file that does not exist.May need to map the COBOL file name to the physical file name. (Micro Focus, refer to the ASSIGN(EXTERNAL) directive). 37 An OPEN Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate Copyright © 1987-2016SimoTime TechnologiesAll Rights Reserved File Status Key Overview The ANS/85 standard provides for a two-byte File-Status-Key. Absence Of Recording Mode Will Cause PreviousVSAM Logical Error Codes NextUseful RACF Commands for Administrators Be the first to comment Leave a Reply Cancel reply Your email address will not be published.CommentName * Email * Website Prove

Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden.Tek-Tips Posting Policies Jobs Jobs from Indeed What: Where: jobs by Link To This Forum! Vsam File Status 39 I do not know what does it mean. Works great! http://www.gatorspit.com/tips/file-status-90.html What is it you want to do with syncsort instead of COBOL.

Are you aComputer / IT professional?Join Tek-Tips Forums! Jcl Error Codes Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework. I am going to explain it. Indicates a duplicate key condition.

Vsam File Status 39

Click to share on Facebook (Opens in new window)Click to share on LinkedIn (Opens in new window)Click to share on Twitter (Opens in new window)Click to share on Google+ (Opens in http://www.simotime.com/vsmfsk01.htm Company Overview Founded in 1987, SimoTime Technologies is a privately owned company. Vsam File Status 90 In Cobol You have reached the end of the file. 12 Attempted to open a file that is already open. 13 File not found. Vsam File Status 93 If you use the sample code shown below, you will see the code in a variable in your program, which you then should test.

go

Home Articles Speaker Gallery Resources About Me Disclaimer Contact Me Recent Articles [ October 26, 2016 ] GSE UK Conference 2016 in Whitlebury, UK (01 – 02 Nov) Tech check my blog Books on Vsam Vsam Manuals / Tutorials VSAM error code, VSAM file status, VSAM/QSAM status key, abend codes error code, file status, status key, VSAM open error, QSAM open error, VSAM All Rights Reserved. Email check failed, please try again Sorry, your blog cannot share posts by email. %d bloggers like this: Into Clause Is Used With

RE: FS 90 reading VSAM sequentialy TonyJollans (Programmer) 29 Mar 04 11:49 Hi josep11477,I think status code of 90 is more likely the result of trying to read past the end SimoTime Technologies shall not be liable for any direct, indirect, special or consequential damages resulting from the loss of use, data or projects, whether in an action of contract or tort, Cancel Red Flag SubmittedThank you for helping keep Tek-Tips Forums free from inappropriate posts.The Tek-Tips staff will check this out and take appropriate action. this content The ascending key requirements of successive record key values has been violated or the prime record key value has been changed by a COBOL program between successful execution of a READ

Refer to the section for Status-Key-1 being equal to "3" for additional information based on Status-Key-2. 4Logic Error, a program is attempting a file access function in an improper sequence or File Status 92 Join Us! *Tek-Tips's functionality depends on members receiving e-mail. VSAM Open error codes 136(88) Not enough Virtual-Storage Space is available for Work Areas, Control Blocks, or Buffers. 144(90) An uncorrectable I/O error occurred while VSAM was Reading or Writing a

Therefore, the file status key may not always be a numeric value that is easy to display.

The combinations of possible values and their meanings are shown below with some comments where vendor additions or extensions may occur. The request cannot be fulfilled by the server Vsam status and file return code 90. Summary This document provides a summary of the two-byte File-Status-Key (sometimes referred to as file return code or file status code). Idcams Verify This can also happen when a sequential file is open for input and an attempt is made to open the same file for output.(Run Time System (RTS) message by Micro Focus).

RE: FS 90 reading VSAM sequentialy Truusvlugindewind (Programmer) 30 Mar 04 05:49 Yes, like Crox says, or embed sort into COBOL using the SORT verb and let COBOL do the I/O. And VSAM has this .namefile.DDMEA that causes problems... It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement. have a peek at these guys The number of significant digits in the relative record number is larger than the size of the relative key data item described for that file.

Alternatively a START or READ operation has been tried on an optional input file that is not present. 24 Relative and indexed files only. We appreciate hearing from you. In Multi threading environment if one process did not close the vsam file and another pgm tried to open it then you would get a file status of 90. SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose.

Following are the common file status codes with their description which will help you to resolve the issues: CodeDescription 00Operation completed successfully 02Non-Unique Alternate Index duplicate key found 04Invalid fixed length Possible causes:Attempting to write beyond the externally defined boundaries of a file.Attempting a sequential WRITE operation has been tried on a relative file, but the number of significant digits in the Is it an input file or an output file? This can be caused by issuing a read after the end-of-file has been reached during sequential processing. 9149 95 Wrong open mode or access mode for REWRITE/ DELETE. 9150 96 Program

If you don't check the code when dealing with QSAM files, the system abends your program in case of serious error, and gives you a system completion code. This is usually caused by a conflict with record-length, key-length, key-position or file organization. ALT INDX' 003500 WHEN '04' DISPLAY 'READ, WRONG LENGTH RECORD' 003600 WHEN '05' DISPLAY 'OPEN, FILE NOT PRESENT' 003700 WHEN '07' DISPLAY 'CLOSE OPTION INCOMPAT FILE DEVICE' 003800 DISPLAY 'OPEN IMPLIES Explore the COBOL Connection for more examples of COBOL programming techniques and sample code.

This document may be used to assist as a tutorial for new programmers or as a quick reference for experienced programmers. We reserve the right to make changes without notice at any time. Here's Why Members Love Tek-Tips Forums: Talk To Other Members Notification Of Responses To Questions Favorite Forums One Click Access Keyword Search Of All Posts, And More... Notify me of follow-up comments by email.

Also, check to see if the path to the file concerned exists (Micro Focus). 14 Relative files only. RE: FS 90 reading VSAM sequentialy josep11477 (Programmer) (OP) 30 Mar 04 05:04 Thanks both, but I still have the problem. There is more to making the Internet work for your company's business than just having a nice looking WEB site. The value is placed in the status key before execution of any EXCEPTION/ERROR declarative or INVALID KEY/AT END phrase associated with the request.

The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies.