Home > File Status > File Status 92 In Cobol

File Status 92 In Cobol

Contents

Ed Goodman Posts: 342Joined: Thu Feb 24, 2011 12:05 am Hasthanked: 3 times Beenthanked: 17 times Top Re: i get logic error 92 when i run this code by jophine89 These tables are provided for individuals that need to better understand the bit structures and differences of the encoding formats. MAIN-RTN. Facebook Twitter Googleplus Youtube Reddit pinterest check over here

You see, when you coded the "SELECT" statement for FILE1, you told COBOL to look to the "DD1" DD statement in the JCL for that data. DISPLAY FS. Open Error Code 39 by jellypuno » Thu May 02, 2013 9:40 am 9 Replies 2511 Views Last post by Robert Sample Thu May 02, 2013 4:32 pm 0C7 Error (System check this link for sample porgram to check the status codes. More about the author

File Status 92 In Cobol

Could also indicate an out of memory situation. 9002 02 File not open when access tried. 9003 03 Serial mode error. 9004 04 Illegal file name.Micro Focus, the COBOL file name ENVIRONMENT DIVISION. check the access mode in file declaration.

READ-SEQ. CLOSE FILE1. If status-key-1 is equal to 9 then status-key-2 is a one byte, binary value as defined in the following table. Vsam File Status 35 It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement.

go

MAINFRAME PROGRAMESSearch this site MaterialHomeJCL NOTESJCL NOTES 2COBOL NOTESDB2 NOTESDB2 NOTES 2CICS NOTESCICS NOTES 2 PROGRAMSJCL PROGRAMSVSAM PROGRAMSCOBOL PROGRAMSDB2 PROGRAMSCICS PROGRAMS INTERVIEW QUESTIONSJCL INTERVIEW QUESTIONSVSAM INTERVIEW QUESTIONSCOBOL INTERVIEW QUESTIONSDB2 Vsam File Status 92 While Writing I can't tell which, but whichever your program is wrong. The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies. Possible causes:Attempting to WRITE or REWRITE a record that is larger than the largest, or smaller than the smallest record allowed by the RECORD IS VARYING clause of the associated file.Attempting

ermanent I/O Error ermanent I/O Error - Record outside file boundary PEN, but file not found PEN with wrong mode ried to OPEN a LOCKed file PEN failed, conflicting file attributes File Status 39 In Cobol The combinations of possible values and their meanings are shown below with some comments where vendor additions or extensions may occur. Using the ACCEPT verb means the system is expecting you to provide input in //SYSIN and the file will be completely ignored -- in which case you risk a S0C4 storage STOP RUN.

Vsam File Status 92 While Writing

MVSFORUMS.comA Community of and for MVS Professionals FAQ Search Quick Manuals Register Profile Log in to check your private messages Log in vsam file status 92 while reading. https://sites.google.com/site/mainframeprogrames/vsam-file-status-codes Explore the COBOL Connection for more examples of COBOL programming techniques and sample code. File Status 92 In Cobol Indicates a boundary violation. Vsam File Status 22 DISPLAY FS.

Explore The Micro Focus Web Site via Internet Connect for more information about products and services available from Micro Focus. check my blog Explore the Assembler Connection for more examples of mainframe Assembler programming techniques and sample code. Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate it appears you are attempting to use one file where you need two files (sequential log file and indexed VSAM file).3. Vsam File Status 23

Hi, Can some one elaborate me what is the file status 92 , while reading the vsam file. VSAM Creatign Utility Advertisements More.. StatusKey-1Description by Group 0Successful Completion or non-terminal condition that may be acceptable to continue processing. this content You, at best, get START, START, READ, START, READ, START, READ...

Also, check to see if the path to the file concerned exists (Micro Focus). 14 Relative files only. Hope this helps... This document and the links to other documents are intended to provide a greater awareness of the Data Management and Application Processing alternatives.

The error may be caused by an invalid key or the sequence of processing for a valid key.

All Rights Reserved. Why are you doing this? We appreciate hearing from you. can you help me out..

SimoTime Technologies shall not be liable for any direct, indirect, special or consequential damages resulting from the loss of use, data or projects, whether in an action of contract or tort, Status1 & 2 Description 00 Successful completion 02 Indexed files only. It's about the business of doing business and looking good in the process. have a peek at these guys Refer to the section for Status-Key-1 being equal to "3" for additional information based on Status-Key-2. 4Logic Error, a program is attempting a file access function in an improper sequence or

once you do a start on the VSAM file, you just read and display until end-of-file. Check the ASSIGN(EXTERNAL) directive and possible environment variable setting for the COBOL file name. 9005 05 Illegal device specification. 9006 06 Attempt to write to a file opened for input. 9007 Many vendors take advantage of the x"00' to x'FF' (or 0-255) binary value. DATA DIVISION.

This is usually caused by a conflict with record-length, key-length, key-position or file organization. FILE-CONTROL. STOP RUN. FD FILE1. 01 BK. 02 LOG PIC X(29).

Current Server or Internet Access The following links may be to the current server or to the Internet. For an OPEN or CLOSE statement with the REEL/UNIT phrase the referenced file is a non-reel/unit medium. 08 Attempted to read from a file opened for output. 09 No room in Usually, it may come when file was not closed.           for example, Comments Sign in|Recent Site Activity|Report Abuse|Print Page|Powered By Google Sites The request cannot be fulfilled by the server File Jobs Send18 Whiteboard Net Meeting Tools Articles Facebook Google+ Twitter Linkedin YouTube Home Tutorials Library Coding Ground Tutor Connect Videos Search Learn VSAM VSAM - Home VSAM - Overview VSAM -

If you don't get a clean start, you can't do a read.I would do something like this in stages. The following tables contain file-status-key content that may be set by Micro Focus COBOL (Mainframe Express or Net Express) or an IBM Mainframe System (MVS, OS/390 or ZOS). Refer to the section for Status-Key-1 being equal to "0" for additional information based on Status-Key-2. 1End of File, attempting to read beyond the end of the file. Company Overview Founded in 1987, SimoTime Technologies is a privately owned company.

This includes the smallest thin client using the Internet and the very large mainframe systems. i then edited the procedure division as follows still i get file status 92. I want to conver that file from sequential to dynamic..