Labview Visa Error -1073807339

Contents

YourFeedback! An input task might stop running if the input buffer overflows. To correct this error, remove either the 0x08 option or the 0x80 and 0x100 options. 1604 The Open VI Reference function does not support using the option 0x08 (Prepare for reentrant Answered Your Question? http://digitalfishbowl.net/error-code/labview-visa-error-codes.html

VI_ERROR_INV_PARAMETER BFFF0078h The value of some parameter--which parameter is not known--is invalid. You must load an instance of the polymorphic VI instead of the polymorphic VI itself. 1125 File version is later than the current LabVIEW version. 1126 VI version is too early My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation. VI_ERROR_WINDOW_NMAPPED BFFF0057h The specified session is not currently mapped. https://zone.ni.com/reference/en-XX/help/371361J-01/lverror/visa_error_codes/

Labview Visa Error -1073807339

VI_ERROR_INV_EVENT BFFF0026h Specified event type is not supported by the resource. Fix the errors before attempting this operation. 1499 Library has edits in another context. If the NI-VISA server is installed and running on the remote machine, it might have an incompatible version or might be listening on a different port. −1073807192 Access to the resource Poor|Excellent Yes No Document Quality?

VI_ERROR_INV_LINE BFFF00A0h The value specified by the line parameter is invalid. This tells you how many bytes that command sends back.Note: If you still receive the error while reading only 1 byte, verify the command to make sure it has been written VI_ERROR_NSUP_LINE BFFF00A3h One of the specified lines (trigSrc or trigDest) is not supported by this VISA implementation, or the combination of lines is not a valid mapping. Visa Declined Codes Unnamed mechanisms do not have this restriction, because each request to obtain an unnamed mechanism creates a new mechanism. 1095 This container cannot be left without a subtype.

VI_ERROR_INV_LENGTH BFFF0083h Invalid length specified. There is at least one more event occurrence of the type specified by inEventType available for this session. 1073676418 The specified object reference is uninitialized. 1073676420 Although the specified state of VI_ERROR_INV_RSRC_NAME BFFF0012h Invalid resource reference specified. This error can occur for several reasons.

This problem might occur due to a type cast error. 1564 Project file cannot be saved at this time. Credit Card Declined Error Codes VI_ERROR_NSUP_ALIGN_OFFSET BFFF0070h The specified offset is not properly aligned for the access width of the operation. Set Segment Headers to One header per segment to correct this error. 1 An input parameter is invalid. VI_ERROR_INV_EXPR BFFF0010h Invalid expression specified for search.

Labview Error Code -1073807339

VI_ERROR_TMO BFFF0015h Timeout expired before operation completed. Wait until the VI is not being modified to get the image of a panel or diagram. 1001 The VI front panel is not open. Labview Visa Error -1073807339 Solution: There are several reasons why you might receive this error message, the most common of which are detailed below: A timeout error is generally indicative of a different problem. Labview Error 1073807339 Additionally, can verify that you are not trying to read too many bytes by reading only 1 byte at a time.

This is usually due to a required driver not being installed on the system. −1073807201 The interface cannot generate an interrupt on the requested level or with the requested statusID value. VI_ERROR_NSUP_WIDTH BFFF0076h Specified width is not supported by this hardware. Add Comments 1 2 3 4 5 My Profile|Privacy|Legal|Contact NI© National Instruments Corporation. You must specify a different location on disk when copying a project library. 1440 The filename does not match the expected name. Ni Error

If it is reentrant, use the Open VI Reference function with the options input set to 0x08 to prepare the VI for reentrant run or use the Open VI Reference function A framing error occurs when a byte of data is received, but it is not in the format expected. The exception might have corrupted the LabVIEW memory. The specified access type is not valid. −1967345148 Invalid argument.

The value for palette width must be 0 or greater. −4403 A palette item is invalid. Ni Visa Verify the values you wired to the Call Library Function Node. 1098 Cannot disconnect type definitions or polymorphic VIs if the block diagram is not available. 1100 No object of that You cannot use this property with a Conditional Disable structure because conditions determine the active frame.

Do not invoke any other handlers on this session for this event. 1073676441 Operation completed successfully, and this session has nested shared locks. 1073676442 Operation completed successfully, and this session has

Refer to the KnowledgeBase for more information about correcting errors in LabVIEW. You cannot use queues for communication between LabVIEW application instances. 1492 If you obtain a notifier reference in one application instance, you cannot use that notifier reference in another application instance. This is due to lack of sufficient privileges for the current user or machine. Credit Card Declined Reason Codes The device will continuously output the data whether the program is on or off.

Completion Codes Values Meaning VI_ERROR_SYSTEM_ERROR BFFF0000h Unknown system error (miscellaneous error). VI_ERROR_INV_MASK BFFF003Dh Invalid buffer mask specified. These VIs have been deprecated so the error is only mentioned here as a note. The 0x08 flag is not useful when performing asynchronous calls.

Check printer configuration. 1016 Cannot load History. 1017 VI has been modified on disk since it was last loaded or saved. 1018 Unspecified error occurred. 1019 One or more untitled subVIs Right-click the Scan From String function and select Edit Format String to configure the format string to match the input data. 87 Error converting to variant. Add Comments 1 2 3 4 5 My Profile|Privacy|Legal|Contact NI© National Instruments Corporation. VI_ERROR_INV_ACC_MODE BFFF0013h Invalid access mode.

VI_ERROR_FILE_IO BFFF00A2h An error occurred while performing I/O on the specified file. VI_ERROR_RAW_RD_PROT_VIOL BFFF0035h Violation of raw read protocol occurred during transfer. To address your instrument, you can either use its VISA Alias or VISA Resource Name.